3 copy pair requirements, 3-1 p-vol requirements, Copy pair requirements – HP XP Command View Advanced Edition Software User Manual
Page 34: P-vol requirements
 
Preparing for and Starting Operations 34
 
 
Third-Party Software Application Requirements
If the third-party software applies to a specific array, Device Manager allows the link and launch of a URL from 
the physical view dialog box or Show Properties - Subsystem Name subwindow for each storage subsystem. 
For details, refer to the HP StorageWorks Command View XP Advanced Edition Device Manager CLI User 
Guide. Specifically refer to the addURLLink, GetURLLink, and DeleteURLLink API commands. 
4-3 Copy Pair Requirements
For details on the Device Manager server requirements, host requirements, and storage subsystem 
requirements that must be fulfilled to perform copy pair operations, see the HP StorageWorks Command View 
XP Advanced Edition Device Manager Server Installation and Configuration Guide. 
This section describes the following requirements that must be fulfilled to create a copy pair:
•
P-VOL requirements (see section
4-3-1
)
•
S-VOL requirements (see section
4-3-2
)
•
RAID level requirements (see section
4-3-3
)
4-3-1 P-VOL Requirements
Requirements for a logical device to be selectable as a primary volume (SP-VOL) for a copy pair differ 
depending on the storage subsystem or copy type. 
Table 4-1
shows the requirements for a logical device to be
selectable as a primary volume.
Table 4-1
Requirements for a logical device to be selectable as a primary volume (SP-volume)
Storage subsystem
Requirements for a logical device to be selectable as a primary volume (SP-volume)
Common to all storage 
subsystems 
Common conditions 
for paired volumes 
•
The logical device must be identifiable to the Device Manager 
agent. You can confirm this by checking whether the date is 
updated to the last update time. However, if the host uses the 
central management method for pair management, the Device 
Manager agent does not need to identify the logical device. 
•
The combination of the RAID levels must satisfy the conditions 
shown in 
Table 4-3
.
•
The LUN security must be set up for the target host.
•
The logical device must be of an open system.
•
The logical device must belong to a storage subsystem for which a 
command device is set up. The command device must not be 
mounted. 
•
The logical device must not be a command device.
If the host uses the central management method for pair management, 
the logical device must be a volume that belongs to the storage 
subsystem for the command device identified by the host that manages 
copy pairs. 
Condition
for
Continuous Access 
XP Synchronous and 
Continuous Access 
XP Extension 
•
The primary volume must not have any secondary volumes.
StorageWorks 
XP12000/XP10000* 
Common condition for 
paired volume 
For an internal volume mapped to an external volume, the host I/O 
suppression mode must be disabled. 
Conditions
for
Continuous Access 
XP* 
•
The logical device must not be a primary or secondary volume for 
Continuous Access XP. 
•
The logical device must not be a primary or secondary volume for 
Continuous Access XP Extension. 
•
The logical device must belong to the CU (MCU) for which the RCU 
is set up. 
•
The logical device must not be a primary volume, V-volume or data 
pool for Snapshot XP.