Accessing the redundant rom, Hp c-class blade suv cable – HP ProLiant BL465c G7 Server-Blade User Manual

Page 11

Advertising
background image

Component identification 11

8.

Repeat steps 1 through 3.

9.

Change position 6 of the system maintenance switch to off.

10.

Repeat steps 5 and 6.

IMPORTANT:

When the server blade boots after NVRAM is cleared, a delay of up to 2

minutes is normal. During this delay, the system appears non-functional. Do not attempt any
procedures during the delay.

Accessing the redundant ROM

If the system ROM is corrupted, the system automatically switches to the redundant ROM in most cases. If

the system does not automatically switch to the redundant ROM, perform the following steps:

1.

Power down the server blade (on page

13

).

2.

Remove the server blade (on page

14

).

3.

Remove the access panel (on page

15

).

4.

Change positions 1, 5, and 6 of the system maintenance switch to on.

5.

Install the access panel (on page

15

).

6.

Install the server blade in the enclosure and power up the server blade.

7.

After the system beeps, repeat steps 1 through 3.

8.

Change positions 1, 5, and 6 of system maintenance switch to off.

9.

Repeat steps 5 and 6.

If both the current and backup versions of the ROM are corrupt, return the system board for a service
replacement.
To switch to the backup ROM when the System ROM is not corrupt, use RBSU.

HP c-Class Blade SUV Cable

Advertising