Running custom tests – HP StoreEver ESL G3 Tape Libraries User Manual

Page 172

Advertising
background image

8.

After the FRU test successfully verifies that the FRU has PASSED or is MARGINAL, all events asso-
ciated with the failure are transitioned to the Verify state.

Running custom tests

The custom tests allow you to run a sub-test that is normally part of the larger tests that call multiple
sub-tests—such as Installation or Partial.

To run custom tests:

1.

Make sure that you are viewing the physical library. From the View menu or in the Managed
Views region of the LMC, click the name of the physical library.

2.

Tools > Library Diagnostics > Verification Tests.

The Verification Tests dialog box appears.

3.

From the Select Test drop-down list, click Custom.

The Select Sub-test field defaults to the Library Alignment sub-test and cannot be changed.

4.

Click Start.

5.

If prompted to take the library offline, click Yes.

The Attention dialog box appears.

6.

Select the number of the module and racks where the you want to perform the tests.

Maintaining the library