HP StorageWorks 1510i Modular Smart Array User Manual

Page 42

Advertising
background image

2.

As needed, expand the drop-down boxes in the task area to change the settings from the suggested

defaults.

NOTE:

• The SMU suggests defaults for the logical drive, creating one large logical drive from all

unused space on the array, with the highest fault tolerance and performance possible

for the hard drives included in that array.

• Only Fault Tolerance levels possible for the array are displayed. For example, RAID 5

is not listed if the array has only two physical hard drives.

• The default Stripe Size gives optimum performance in a mixed read/write environment.

• For read-prominent environments, use a larger stripe size.
• For write-prominent environments, use a smaller stripe size for RAID 5 or

RAID_ADG, and a larger stripe size for RAID 0 or RAID 1+0.

• To build multiple logical drives on the same array, reduce the Size setting from the

default to a smaller amount. Additional logical drives can then be built from the

remaining unused space.

• Disabling the Array Accelerator for a logical drive reserves use of the accelerator

cache for other logical drives in the array. This feature is useful if you want the other

logical drives to have the maximum possible performance.

3.

When the display refreshes, verify that the configured logical drives are shown in the component list.

4.

Repeat

Step 1

through

Step 3

to create additional logical drives for this array, or to create logical

drives for other arrays.

Configuration status - after configuring hard drives

Figure 10

illustrates the current configuration.

The following items are configured:

Management port MA0 and MB0

Data ports SA0, SA1, SB0, and SB1

Physical hard drives, into:
• Array A—Four (4) 160 GB hard drives, with no assigned spare

• Logical drive 1—RAID 1+0

• Array B—Three (3) 250 GB hard drives, with an assigned spare

• Logical drive 2—RAID 5

• Array C—Three (3) 250 GB hard drives, with an assigned spare

• Logical drive 3—RAID 5

42

Configure

Advertising