Using the Command Line Interface 56

<target> modify redundantcontroller=disable

where

<target>

is a controller that has an enabled redundant controller.

Example command:

=> ctrl ch="redundant Lab4" modify rc=disable

Setting the target

If you must perform several operations on a given target device, you can simplify the required commands
by setting the device as the default

<target>

for the CLI operations.

After you have set the target, any command that you enter in the CLI without a specified

<target>

is

automatically applied to the set target. If you must also perform operations on other devices, you can still
do so at any time by specifying the

<target>

for each of those operations as usual. You can also

change the set target or clear it completely. The set target is automatically cleared when you close the CLI.

IMPORTANT: You cannot use the

set target

command in batch file scripts.

Syntax:

set target <target>

where

<target>

is a controller, array, or logical drive.

Example commands:

=> set target ctrl slot=3

=> clear target

Typical scenario

First, set a target as follows:

=> set target ctrl ch="Lab 4"

=> show target

controller chassisname="Lab 4"

As an example of how the set target command works, check the status of array A on this controller:

=> array A show

MSA1000 at Lab 4

array A

Interface Type: Parallel SCSI

Unused Space: 7949 MB

Status: OK

Note that the controller does not need to be specified because it is currently the set target.

Now clear the target, reset it, and enter a few commands for the new set target:

=> clear target

=> set target ctrl slot=3

=> array A add drives=1:7,1:8,1:9

=> array B add spares=1:10,1:11

=> ctrl slot=4 ld 3 modify ss=64

=> modify rp=high

This sequence includes a command for a different target (the controller in slot 4) as a demonstration. Note
that the next command in the sequence (the one for modifying the rebuild priority) applies to the controller
in slot 3, not the one in slot 4. This is because the command does not specify a

<target>

for the rebuild

priority, so the default set target is used instead.