HP XP7 Storage User Manual

Page 151

Advertising
background image

Causes and Solutions

Problems

•

Adjust the value of Subscription Limit for the pool. See

“Changing

the pool subscription limit” (page 130)

.

•

Ask HP Technical Support to solve the problem.

Causes:

Cannot add a pool-VOL.

•

1,024 pool-VOLs are already defined in the pool.

•

The pool-VOL does not fill the requirements for a pool-VOL.

•

Something in the storage system is blocked.

Solution:

•

Change the setting of the LDEV to satisfy the requirement of the
Pool-VOL. See

“Pool-VOL requirements” (page 55)

.

Causes:

•

A failure occurred in data drives greater than the parity group
redundancy. The redundancy of the parity group depends on the
number of the blocked PDEVs (data drives). For example:

◦

When the parity group configuration is 3D+1P and failures occur
in two or more drives, the failures are considered to have occurred
in data drives beyond the parity group redundancy.

◦

When the parity group configuration is 6D+2P and failures occur
in three or more drives, the failures are considered to have
occurred in data drives beyond the parity group redundancy.

Solutions:

•

Ask HP Technical Support to solve the problem.

A pool-VOL is blocked. SIM code 627XXX is
reported.

Solutions:

•

Ask HP Technical Support to solve the problem.

A pool is blocked.

Causes:

A pool cannot be restored.

•

Processing takes time, because something in the storage system is
blocked.

•

Usage of the pool has reached to 100%.

Solutions:

•

After waiting for a while, refresh the display, and check the pool
status.

•

Add some pool-VOLs to the pool to increase the capacity of the pool.
See

“Increasing pool capacity” (page 134)

).

•

Perform the operation to reclaim zero pages in order to release pages
in which zero data are stored. See

“About releasing pages in a THP

V-VOL” (page 141)

.

•

Ask HP Technical Support to solve the problem.

Causes:

A pool cannot be deleted.

•

The pool usage is not 0.

•

External volumes are removed from the pool before you delete the
pool.

•

THP V-VOLs have not been deleted.

Solutions:

•

Confirm that the pool usage is 0 after the THP V-VOLs are deleted,
and then you can delete the pool.

•

Ask HP Technical Support to solve the problem.

Troubleshooting Thin Provisioning Z

151

Advertising
This manual is related to the following products: