Performance Monitor

The following table provides information about specific Performance Monitor conditions that must
be observed when using Resource Partition.

Condition

Operation name

The specified ports must be assigned to the Storage Administrator group permitted
to manage them.

Add to ports

The specified ports must be assigned to the Storage Administrator group permitted
to manage them.

Add new monitored WWNs

The specified ports must be assigned to the Storage Administrator group permitted
to manage them.

Edit WWNs

Business Copy Z

The following table provides information about specific Business Copy Z conditions that must be
observed when using Resource Partition.

Condition

Operation name

Both primary volumes and secondary volumes must be assigned to the Storage
Administrator group permitted to manage them.

Create pairs

Primary volumes must be assigned to the Storage Administrator group permitted
to manage them.

Split pairs

Suspend pairs

Resynchronize pairs

Release pairs

Continuous Access Synchronous Z

The following table provides information about specific Continuous Access Synchronous Z conditions
that must be observed when using Resource Partition.

Condition

Operation name

Specified ports must be assigned to the user.

Edit Ports

Specified initiator ports must be assigned to the user.

Add Remote Connection

Operation can be performed with no conditions.

Edit Remote Connection Options

Primary volumes must be assigned to the user.

Create Pairs

Initiator ports of remote paths that are connected with the primary volume in the
remote storage must be assigned to the user.

Specified primary volumes or secondary volumes must be assigned to the user.

Split Pairs

Primary volumes must be assigned to the user.

Resync Pairs

Specified volumes must be assigned to the user.

Delete Pairs

If primary volumes are specified, the initiator ports of remote paths that are
connected with the primary volume in the remote storage must be assigned to the
user.

Primary volumes must be assigned to the user.

Edit Pair Options

Specified initiator ports must be assigned to the user.

Add Remote Paths

Specified initiator ports must be assigned to the user.

Remove Remote Paths

Using Resource Partition and other HP XP7 Storage products