Is the drive module fault/uid led blinking amber – HP StorageWorks 2000fc G2 Modular Smart Array User Manual

Page 45

Advertising
background image

HP 2312fc and 2324fc Modular Smart Array user guide

45

Are both drive module LEDs off (Online/Activity and Fault/UID)?

Is the drive module Fault/UID LED blinking amber?

Is a connected host port’s Host Link Status LED off?

Answer

Possible Reasons

Actions

Yes

•

There is no power.

•

The drive is offline.

•

The drive is not configured.

•

Check that the drive is fully inserted

and latched in place, and that the

enclosure is powered on.

Answer

Possible Reasons

Actions

No, but the

Online/Activity LED is

blinking.

The drive is rebuilding.

No action required.

NOTE:

Do not remove a drive that is

rebuilding. Removing a drive might

terminate the current operation and

cause data loss.

Yes, and the

Online/Activity LED is off.

The drive is offline. A predictive

failure alert may have been

received for this device.

•

Check the event log for specific

information regarding the fault.

•

Isolate the fault.

•

Contact an authorized service

provider for assistance.

Yes, and the

Online/Activity LED is

blinking.

The drive is active, but a

predictive failure alert may have

been received for this device.

•

Check the event log for specific

information regarding the fault.

•

Isolate the fault.

•

Contact an authorized service

provider for assistance.

Answer

Possible Reasons

Actions

No

System functioning properly.

No action required.

Yes

The link is down.

•

Check cable connections.

•

Reseat cables.

•

Replace cables.

•

In SMU, review the event logs for

indicators of a specific fault in a

host data path component.

Advertising