Power supply module voltage sensors, 9 power supply temperature sensors, 10 voltage sensor descriptions – HP StorageWorks 2000fc G2 Modular Smart Array User Manual
Page 52

52
Troubleshooting
When a power supply sensor goes out of range, the Fault/ID LED illuminates amber and an event is
logged to the event log.
Power supply module voltage sensors
Power supply voltage sensors ensure that an enclosure’s power supply voltage is within normal ranges.
There are three voltage sensors per power supply.
Onboard temperature 1
0–70
°C
None
None
None
Onboard temperature 2
0–70
°C
None
None
None
Onboard temperature 3
(Capacitor temperature)
0–70
°C
None
None
None
CM temperature
5–50
°C
<=5
°C,
>= 50
°C
<=0
°C,
>= 55
°C
None
Table 9
Power supply temperature sensors
Description
Normal operating range
Power Supply 1 temperature
–10–80°C
Power Supply 2 temperature
–10–80°C
Table 8
Controller module temperature sensors (continued)
Description
Normal operating
range
Warning
operating range
Critical operating
range
Shutdown values
Table 10
Voltage sensor descriptions
Sensor
Event/Fault LED condition
Power supply 1 voltage, 12V
< 11.00V
> 13.00V
Power supply 1 voltage, 5V
< 4.00V
> 6.00V
Power supply 1 voltage, 3.3V
< 3.00V
> 3.80V