Troubleshooting, General truecopy troubleshooting – HP StorageWorks XP Remote Web Console Software User Manual

Page 151

Advertising
background image

Hitachi TrueCopy for z/OS user guide 151

2.

Halt the applications at the remote site and vary the M-VOLs (original R-VOLs) offline at the remote site.

This maintains synchronization of the TC390 Synchronous pairs.

3.

At the remote site, suspend all TC390 pairs at the MCUs (original RCUs) to destage any pending data

from cache. Confirm that the pairs are suspended before proceeding. If an error occurs, resolve it

before proceeding.

4.

At the remote site, delete all TC390 pairs at the MCUs (original RCUs) using the Delete All Pairs option

for TC390 sync pairs and the Delete-Group option for TC390A pairs. For TC390A pairs, the MCU and

RCU complete all pending updates before changing the pair status to simplex.

5.

At the remote site, change the TC390 settings at the MCUs (original RCUs) to prepare for normal

TC390 operations. Delete the TC390A groups and the RCUs (original MCUs). If you plan to use the

same remote copy connections, reconfigure the ports (change RCPs back to LCPs for serial, change

initiator ports back to ordinary target ports for fibre). If system option mode 114 is enabled on all MCUs

and RCUs, the ports will reconfigure automatically if you use the TSO CESTPATH command to add the

pairs at the main site.

NOTE:

For Fibre Channel interface, do not use the CESTPATH and CDELPATH commands at the

same time as the SCSI path definition function of LUN Management. The Fibre Channel interface

ports need to be configured as initiator ports or RCU target ports before the CESTPATH and

CDELPATH commands are issued.

6.

If you plan to use the same channel extenders, change the operating mode back to the original

direction. The boxes/nodes connected to the MCUs must be set to channel-mode and the boxes/nodes

connected to the RCUs must be set to device-mode.

7.

At the main site, configure the RCPs or initiator ports, add the RCUs, and add the TC390A groups. If

system option mode 114 is enabled on all MCUs and RCUs, the ports will reconfigure automatically if

you use the TSO CESTPATH command to add the pairs at the main site.

CAUTION:

Before issuing the CESTPATH command, verify that the relevant paths are offline from

the host(s) (for example, configure the Chipid offline, deactivate the LPAR, or block the port in the

ESCD). If any active logical paths still exist, the add path operation will fail because the port mode

(LCP/RCP) cannot be changed.

8.

At the main site, establish all TC390A groups and TC390 pairs in the original direction. You may use

the No Copy initial copy option because all M-VOLs and R-VOLs are synchronized. If there is any

possibility that the volumes are not 100% synchronized, use the Entire initial copy option to be safe.

9.

Vary the MCU and M-VOLs online and start the applications at the main site.

Troubleshooting

General TrueCopy troubleshooting

In the unlikely event of a problem with the XP Command View Advanced Edition or XP Remote Web

Console software, first verify that the problem is not being caused by the PC or Ethernet hardware or

software, and then try restarting the PC. Restarting the XP Command View Advanced Edition Software

server does not affect TC390 operations already in progress. For a description of the TC390 error

messages displayed on the XP Command View Advanced Edition Software server or XP Remote Web

Console, see

TrueCopy software error codes

” on page 156.

NOTE:

Use the FDCOPY function to copy the XP Command View Advanced Edition Software or XP

Remote Web Console configuration information onto diskette and give the diskette(s) to HP service

personnel.

The following table provides general troubleshooting information for TC390.

Table 30

on page 153

provides troubleshooting information for RCU paths.