Domain management 23

Domain management

Domain overview

A basic Virtual Connect domain includes a single HP c-Class BladeSystem c7000 Enclosure for a total of
16 servers (or up to 32 servers if the double-dense option is enabled), or a single HP c-Class BladeSystem

c3000 Enclosure for a total of 8 servers (or up to 16 servers if the double-dense option is enabled).

Within the domain, any server blade can access any LAN or SAN connected to a VC module, and a

server blade can be used as a spare for any server blade within the same enclosure.
Version 2.10 and higher supports multiple enclosures, allowing up to four c7000 enclosures to be

managed within a single Virtual Connect domain for a total of 128 servers. Multiple enclosure domains

are not supported on c3000 enclosures.
By stacking (cabling) the Ethernet modules within the domain and connecting the FC modules to the same

set of FC SANs, every server blade in the domain can be configured to access any external network
connection. With this configuration, the Virtual Connect Manager can deploy and migrate a server blade

profile to any server in the Virtual Connect domain without the need to change external LAN or SAN

configurations.

Enclosure serial numbers

The enclosure serial number is used by the Virtual Connect Manager to associate a Virtual Connect

domain with a particular enclosure. The enclosure serial number can be altered for maintenance
purposes, such as replacement of the enclosure midplane. For more information, see SET ENCLOSURE

SERIAL_NUMBER in the HP BladeSystem Onboard Administrator Command Line Interface User Guide.

Enclosure serial numbers are unique as shipped from the factory, and must remain unique for proper
Virtual Connect Manager operation. Use care when altering the enclosure serial number to ensure

that serial numbers are unique within the management network.

After an enclosure is imported into a domain, do not change the serial number. The enclosure must
have the enclosure serial number that was present when imported initially. It cannot be replaced with

an enclosure that has a different serial number.

In the event of an enclosure failure, the replacement enclosure must have the serial number set to that
of the failed enclosure before it is placed into the VC domain.

Domain Settings (Domain Configuration) screen

Use this screen to change the domain name or delete a domain.
The Remove from Domain feature (also known as administrative removal) enables users to remove an

interconnect module from the Virtual Connect domain without having to delete the entire domain, or

having the bay permanently configured for a specific interconnect module type. After an Ethernet module
has been physically removed from the enclosure and none of its ports are part of an Ethernet network