Serial number (logical) settings – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual

Page 117

Advertising
background image

Server management 117

With Virtual Connect Manager v2.10, always power off server blades, with Flex-10 connections, in the

following instances:

Changing a connection's network:

o

From "unassigned" to a single network

o

From a single network to "unassigned"

o

From "unassigned" to multiple networks

o

From multiple networks to "unassigned"

Changing the requested bandwidth

Adding a connection that is mapped to Flex-10

Removing a connection that is mapped to Flex-10

Assigning a profile to a server that maps Flex-10 connections

Unassigning a profile with Flex-10 connections

Flex-10 connection changes that do not require power off
With Virtual Connect Manager 2.10, it is not necessary to power off the server blade, with Flex-10

connections, in the following instances:

Changing a connection network:

o

From a single network to another single network

o

From a single network to multiple networks

o

From multiple networks to a single network

Modifying the networks or VLAN IDs in a connection with multiple networks

Serial Number (Logical) Settings

The serial number (logical) setting feature enables users to add a serial number (logical) and UUID

(logical) to server profiles. By configuring Virtual Connect to assign serial numbers (logical), a profile can

present a single serial number regardless of the physical server. With these configuration values added to
server profiles, software that is licensed to a particular server, based on one or both of these values, can

be migrated to new server hardware without re-licensing the software for the new server hardware. This

features prevents the user from having to reinstall serial number sensitive software after a system recovery.
If a user needs to access the physical serial number of a server blade, the OA displays both the physical

and serial numbers (logical).
After server profile creation, the following guidelines apply:

Serial numbers (logical) can be changed from factory default to VC-assigned.

Factory default serial numbers cannot be changed to serial numbers (logical).

User-defined serial number (logical) ranges can be expanded.

User-defined serial number (logical) ranges cannot be reduced.

All components must be at the required versions or the feature does not function:

o

OA, v2.20 or higher

o

iLO, v1.60 or higher