Example 5-2, Ndconfig on \bck – HP NonStop G-Series User Manual

Page 58

Advertising
background image

Switchovers

ServerNet Nomadic Disk User’s Guide— 425485-001

5 -4

Moving the Fiber Optic Switches to the Opposite

Position

Moving the Fiber Optic Switches to the Opposite
Position

A switch card determines the position of the fiber-optic switch: straight or crossed. To
move the fiber-optic switches to another position, do one of the following:

•

If you are using Nomadic Disk Manager, the GIVE command performs the
switching.

•

If you are not using Nomadic Disk Manager:

•

Issue commands from the Switch Command Interface (SWCI) to each switch.
See

Section 6, Switch Command Interface (SWCI)

. The SWCI commands affect

the switch card only if the key switch on the switch controller card is set to the
REMOTE position.

•

Physically move the toggle switches. The toggle switches affect the switch card
only if the key switch on the switch controller card is set to the LOCAL
position.

Example 5-2. NDCONFIG on \BCK

SET PATH P $ MOD1.#A 1 CROSSED
SET PATH B $ MOD1.#A 2 CROSSED
SET PATH M $TRM1.#A 1 STRAIGHT
SET PATH MB $ TRM1.#A 2 STRAIGHT
SET VOL $DATA01
SET VOL $DATA02
SET VOL $DATA03
SET VOL $DATA04
SET VOL $DATA05
SET VOL $DATA06
SET VOL $DATA07
SET VOL $DATA08

ADD SEGMENT SEGMENT-1, DATA

Advertising