Drive, Drivetype, Onlinespare – HP SmartStart-Software User Manual

Page 44

Advertising
background image

Toolkit utilities 44

In Reconfigure mode, ACU can either create a new array or reconfigure an existing array. In this

case, the value that you specify can identify an existing array, or it can correspond to the next
available array letter or pair of letters in the existing configuration.

Drive

You can use this option to add a drive to an existing array (to expand an array) or to build a new array.

If you are expanding an array, each drive that you add must have a capacity no less than that of the
smallest drive already in the array. The added drives and the existing drives in the array must all be the
same type (for example, SAS or SATA).
If the value of the ClearConfigurationWithDataLoss (on page

41

) option is Yes, you can use

the Drive option to remove drives from an array. However, the

ClearConfigurationWithDataLoss option is now deprecated.
If you use Auto method mode, ACU configures all the available drives on the controller into one array. If

the drives are of different capacities, ACU determines the capacity of the smallest drive and uses the same
amount of space on all other available drives.
If you use Custom method mode, choose one of the following methods to specify the drives to be used in

the array. (Different arrays on the same controller can use different methods.)

To specify individual drives, use the applicable convention (port:ID, box:bay, or port:box:bay).

To specify only the number of drives to use (not which specific drive IDs to use), enter that number as
the value for this option. For example, if you enter drive=3, ACU uses the first three available

drives to build or expand the array that you define in the remainder of the script. ACU automatically

determines which drives are suitable to use.

To use all available drives, enter an asterisk as the value for this option. An array that is configured

using this method cannot have a spare.

DriveType

The value that you enter for this option specifies the type of drive (SAS, SATA, or parallel SCSI) that ACU
must use to build the array.

OnlineSpare

The value for this option determines whether the array specified previously in the script will be configured
with spare drives.

Method mode

Possible values

Default value

Custom

To specify exactly which drives to use as
spares, use the applicable convention (port:ID,

box:bay, or port:box:bay).
To specify only the number of spares (not the

exact IDs), enter that number as the value for
this option. ACU automatically selects only

those drives that are suitable for the array.
To specify that the array should not have

spares, enter None.

In Configure action mode: None
In Reconfigure action mode, ACU
ignores any value entered for this
option and keeps any spares that

are already present in the
configuration