Troubleshooting, Troubleshooting table – HP SmartStart-Software User Manual

Page 61

Advertising
background image

Troubleshooting 61

Troubleshooting

Troubleshooting table

Issue

Troubleshooting

Data loss in Toolkit

Improper use of the Toolkit utilities and modification of the CONREP data files can

result in loss of critical data. Because of the potential data-loss risk, only
experienced individuals should use the Toolkit utilities. Before using the Toolkit, all

necessary precautions must be taken to ensure that mission-critical systems remain
online if a failure occurs.

Setting up a PXE boot

environment

A basic understanding of DHCP, PXE, and TFTP is required to perform the

procedure. The examples in this guide might not be specific to your operating
system environment. For more information about your particular environment, see

the Linux system administrator's guide

Configuring options

using Toolkit utilities

Not all options can be configured using Toolkit utilities. Some options must be

configured manually or with other configuration utilities, which are available
online, before they can be used with the Toolkit. For more information on

configuration, see the option documentation

Input files for

HPONCFG

Because the -w argument does not capture certain types of information, such as the

administrator password, data files created with HPONCFG using the -w argument
cannot be used as input files for HPONCFG, unless they are modified first.

CONREP version

compatibility

The file format for the DOS version of CONREP and the current version of CONREP

are not compatible.

HPACUSCRIPTING
support

HPACUSCRIPTING supports only HP Smart Array controllers. Review the
HPACUSCRIPTING documentation for the latest information.

Booting from a USB
drive key

Booting from a USB drive key is supported only on certain ProLiant servers. For
more information, see the HP Insight Foundation suite for ProLiant website

(

http://www.hp.com/go/foundation

).

CONREP data file

editor

Only the fields that are present in the CONREP file being edited will be shown. The

CONREP data file editor cannot add or remove fields. Some fields, such as the
server OS selection, cannot be edited.

Kernels

The kernel is generally static and cannot be modified easily. HP recommends that
you use the kernel that is shipped with the Toolkit because it has been tested on all

servers supported by the Toolkit.

SETBOOTORDER

changes

Any changes you make to the SETBOOTORDER will take effect at the next reboot.