Esl9000 series issues – HP Command View for Tape Libraries Software User Manual

Page 250

Advertising
background image

“ESL9000 Series issues” (page 250)

“ESL E-Series issues” (page 252)

“EML E-Series issues” (page 254)

“MSL issues” (page 256)

“ESKM enrollment issues” (page 256)

ESL9000 Series issues

Solution

Possible cause

Symptom

Verify that the Interface Manager card
and the management station are
correctly connected to the LAN.

Bad network connection

Command View TL server does not
detect the Interface Manager card

Power up the library. Observe status
and link LEDs. For a description of LED

Interface Manager card not powered
up or in ready state

diagnostic codes, see

LED diagnostic

codes (page 249)

.

Verify that the correct IP address of the
Interface Manager card is entered in
Command View TL.
See

Adding and removing

libraries (page 27)

to configure

Incorrect IP address

Command View TL with the correct IP
address.

Verify that the Interface Manager card
has I130 or later firmware.

Interface Manager card has outdated
firmware

Verify that the Interface Manager card
is properly connected to the FC

Bad network connection

Interface Manager card does not
detect one or more FC interface
controllers

interface controllers and that the cables
are good.

Ensure that the FC interface controllers
have the latest firmware revision. Check

Incorrect firmware revision

http://www.hp.com/support

for the

latest firmware for your devices.

Observe status and link LEDs. Replace
defective card or controller.

Defective Interface Manager card or
FC interface controller

DHCP must be enabled on the interface
controller before the Interface Manager

DHCP not enabled on the interface
controller

card can communicate with it. See the
interface controller documentation for
instructions on enabling DHCP mode.

NOTE:

HP recommends resetting all

interface controllers to their default
settings.

Check SCSI cabling.

SCSI cables not connected properly

Interface Manager card does not
detect drives or library

Check FC cables and replace if
necessary. Use link LEDs to troubleshoot
connections and cable integrity.

FC cables (e2400-FC 2G or 4G only)
not connected properly or damaged

250 Troubleshooting

Advertising