HP XP P9000 Auto LUN Software User Manual

Page 42

Advertising
background image

Table 18 RAID Manager Errors Related to Manual Migration Plans (continued)

Required Action

Message

Error Code
(SSB2)

Tiers virtual volumes that are associated with the
same pool.

Release the pair containing the migration source
volume, and then migrate the volume.

The migration source volume is used by Continuous
Access Synchronous or Continuous Access Journal.

2096

The migration target volume is a Thin Provisioning
or Smart Tiers virtual volume.

Perform the migration plan at least 40 minutes
after the system configuration is changed.

The specified volume cannot be migrated because
the information about system configuration updates
due to volume migration is being backed up.

2098

None. This migration plan cannot be executed.

The volume cannot be migrated if the emulation
type of either the migration source volume or the

2099

migration target volume is OPEN-0V. To migrate
the volume, ensure that the emulation type of both
volumes is OPEN-0V.

None. This migration plan cannot be executed.

Migration is not allowed between the normal
volume specified as a LUSE volume and the Thin
Provisioning or Smart Tiers virtual volume.

209A

Wait until the capacity increase is completed.
Then, you must specify a target volume which has

The migration source volume is a Thin Provisioning
or Smart Tiers virtual volume whose capacity is
increasing.

20A5

the same capacity as the volume whose capacity
is increased and migrate the volume.

Wait until the capacity increase is completed.
Then, you must specify a source volume which has

The migration target volume is a Thin Provisioning
or Smart Tiers virtual volume whose capacity is
increasing.

20A6

the same capacity as the volume whose capacity
is increased and migrate the volume.

Wait until the Thin Provisioning or Smart Tiers
virtual volume discards zero data, and then
migrate the volume.

The migration source volume is a Thin Provisioning
or Smart Tiers virtual volume in which the zero
data are being discarded.

20AD

Wait until the Thin Provisioning or Smart Tiers
virtual volume discards zero data, and then
migrate the volume.

The migration target volume is the Thin
Provisioning or Smart Tiers virtual volume in which
the zero data are being discarded.

20AE

Set an LU path to the volume and then migrate the
volume.

The volume specified as a migration source volume
has no LU path.

20BA

Set an LU path to the volume and then migrate the
volume.

The volume specified as a migration target volume
has no LU path.

20BB

Release the Compatible FlashCopy pair, and then
migrate the volume.

The migration source volume is the primary or
secondary volume of Compatible FlashCopy.

22FA

Release the Compatible FlashCopy pair, and then
migrate the volume.

The migration target volume is the primary or
secondary volume of Compatible FlashCopy.

22FB

Install Auto LUN, and then migrate the volume.

Auto LUN is not installed on the storage system.

2301

Check the configuration information of your
storage system.

The shared memory which is necessary to use Auto
LUN is not installed or the initial setting is not
completed.

2302

None. This migration plan cannot be executed.

The LBA size does not match between the
migration target volume and the migration source
volume.

2306

Reduce the number of pairs set in the storage
system, and then migrate the volume.

The maximum number of pairs which can be set
in the storage system is exceeded.

2309

42

Using RAID Manager for manual Auto LUN

Advertising
This manual is related to the following products: