Add fc-connection, Syntax, Parameters – HP Insight Management-Software User Manual

Page 38: Output

Advertising
background image

add fc-connection

The -add fc-connection command adds a new FC connection to a server profile.

Syntax

-add fc-connection –profilename <profileName>
-connectionbay <ConnectionBay>
[-fabric <FabricName>]
[-speed <auto|1Gb|2Gb|4Gb|8Gb|disabled>]

Parameters

Table 13 Parameter descriptions for -add fc-connection

Optional

Required

Description

Parameter

x

Specifies the name of an
existing profile to add the
new connection to.

-profilename

x

Specifies the bay for the
connection.

-connectionbay

x

Specifies the name of an
existing fabric to associate

-fabric

with the connection. If the
fabric name is not specified,
then the connection will be
marked as unassigned
but associated with a
specific bay.

x

Specifies the port speed of
the connection port. Valid

-speed

values include auto, 1Gb,
2Gb

, 4Gb, 8Gb, and

disabled

. The default port

speed is auto.

NOTE:

For HP 4Gb VC-FC

Modules or HP Virtual
Connect 4Gb FC Modules,
supported speed values
include: auto, 1Gb, 2Gb,
4Gb

, and disabled. If it is

set to 8Gb, VC
auto-negotiated the speed.

Output

The function returns the result of the add operation or a jobid if –nb is specified.

38

Using VCEM commands

Advertising