64 if both nodes use the same external array, N in, Figure 64 – HP StorageWorks XP Remote Web Console Software User Manual

Page 113

Advertising
background image

External Storage XP user guide 113

NOTE:

In the configuration in

Figure 64

, HP recommends setting alternate paths to prevent the NAS

Blade system from being blocked because of the path failure. For more information, see ”

Alternate paths

on page 22.

The situation in

Figure 64

is as follows:

None of the user LUs can be used from node 1 or node 2.

Clients cannot access volumes.

The local array recognizes that the status of all file systems and volumes are blocked.

Figure 64

If both nodes use the same external array

1.

Restore (for example, check the cable’s connection status or change the switch) the status of the error

path between the local array and external array 1.

2.

Execute the Check Paths & Restore Vol. command using External Storage XP. For instructions, see

Checking the connection status and resuming external LU operations (Check Paths & Restore Vol.)

” on

page 100.

3.

Perform the forced stop operations using NAS Blade Manager for resource group 1 and resource

group 2.

4.

Stop the cluster using NAS Blade Manager.

5.

Restart NAS OS 1 and NAS OS 2 (NAS channel adapter’s OS) using LUN Manager or NAS Blade

Manager.

6.

Start the cluster using NAS Blade Manager.

7.

Start resource group 1 and resource group 2 using NAS Blade Manager.