130 Notes on connecting external arrays

Path status and examples of recovery procedures (Thunder 9500V subsystems)

Table 16

shows examples of recovery procedures when the path status is not normal. When the path

status is not normal, see

Troubleshooting External Storage XP

” on page 121 and this table to recover the

path status. If you cannot restore the path, contact you HP account support representative.

Connecting TagmaStore AMS and TagmaStore WMS subsystems

System parameters for connecting TagmaStore AMS and TagmaStore WMS

subsystems

Table 17

explains whether to specify system parameters when making settings for ports on TagmaStore

AMS and TagmaStore WMS subsystems.

Table 16

Path status and examples of recovery procedures (Thunder 9500V subsystems)

Path status

Examples of recovery procedures

External device setting changed

LUN Manager may have changed the LU paths’ settings.
Check the LU paths’ settings. If the LU paths’ settings changed, change the

settings back to the ones used when the volume was mapped. Or use

External Storage XP to perform the Delete LU operation, and perform the

Add LU operation again.

Open LDEV Guard may have changed the volume’s access attribute.
Check the volume’s access attribute. If the volume is protected by the

access attribute, release the protection.

Illegal request

The volume may have been set as a pair volume for data copy.
Check if the volume is set as a pair volume for Business Copy XP,

Continuous Access XP, or another copy program. If the volume is set as a

pair volume, the volume might be protected because of the pair status. If

the volume is protected, change the pair status or delete the pair.

Open LDEV Guard may have changed the volume’s access attribute.
Check the volume’s access attribute. If the volume is protected by the

access attribute, release the protection.

Response error

The volume may have been set as a pair volume for data copy.
Check if the volume is set as a pair volume for Business Copy XP,

Continuous Access XP, or another copy program. If the volume is set as a

pair volume, the volume might be protected because of the pair status. If

the volume is protected, change the pair status or delete the pair.

Open LDEV Guard may have changed the volume’s access attribute.
Check the volume’s access attribute. If the volume is protected by the

access attribute, release the protection.

Cannot detect port

There is a problem with the connection to the external array. The following

are possible causes:

The fibre cable is not connected properly.

The topology setting between the external and target ports does not

match.

If the external array is connected through switches, the switches’

settings might not be appropriate.

Check if the fibre cable is connected properly, and use LUN Manager to

set the Fibre Channel port properly.

LUN Manager may have enabled host group security.
Check if host group security is enabled. If host group security is enabled,

disable host group security.