Connecting eva arrays, Identifying logical, Volumes of eva arrays (using characteristic 2) – HP StorageWorks XP Remote Web Console Software User Manual

Page 138: Identifying logical volumes of eva arrays (using, Characteristic 2)

Advertising
background image

138 Notes on connecting external arrays

Path status and examples of recovery procedures (SVS200)

Figure 24

shows examples of the recovery procedures when the path status is not normal. When the path

status is not normal, use ”

Troubleshooting External Storage XP

” on page 121 and this table to recover the

path status. If you cannot restore the path, contact your HP account support representative.

Connecting EVA arrays

Identifying logical volumes of EVA arrays (using Characteristic 2)

When the connected external array is an EVA array, LUNs are displayed as Characteristic in External

Storage XP’s panes.

Table 24

Path status and examples of recovery procedures (SVS200)

Path Status

Examples of Recovery Procedure

External device setting changed

LUN Manager might have changed the LU paths’ settings.
Check the LU paths’ settings. If the LU paths’ settings changed, change

the settings back to the ones when the volume was mapped. Or use

External Storage XP to perform the Delete LU operation, and perform

the Add LU operation again.

LUN Security XP Extension might have changed the volume’s access

attribute.
Check the volume’s access attribute. If the volume is protected by the

access attribute, release the protection.

Illegal request

The volume might have been set as a pair volume for data copy.
Check if the volume is set as a pair volume of Business Copy XP,

Continuous Access XP, Continuous Access XP Journal, or some other

copy program. If the volume is set as a pair volume, the volume might

be protected because of the pair status. If the volume is protected,

change the pair status or delete the pair.

LUN Security XP Extension might have changed the volume’s access

attribute.
Check the volume’s access attribute. If the volume is protected by the

access attribute, release the protection.

Response error

The volume might have been set as a pair volume for data copy.
Check if the volume is set as a pair volume of Business Copy XP,

Continuous Access XP, Continuous Access XP Journal, or some other

copy program. If the volume is set as a pair volume, the volume might

be protected because of the pair status. If the volume is protected,

change the pair status or delete the pair.

LUN Security XP Extension might have changed the volume’s access

attribute.
Check the volume’s access attribute. If the volume is protected by the

access attribute, release the protection.

Cannot detect port

There is a problem with connection to the external array. The following

are possible causes:
• The fibre cable is not physically connected properly.
• The topology setting does not match between the external and

target ports.

• If the external array is connected through switches, the switches’

settings might not be appropriate.

Check if the fibre cable is connected properly, and then set the Fibre

Channel port properly using LUN Manager.

LUN Manager might have enabled LUN security.
Check if the LUN security is enabled or not. If LUN security is enabled,

disable LUN security.

Advertising
This manual is related to the following products: