background image

Hardware options installation 56

7.

Connect any required internal or external cables to the expansion board. See the documentation that
ships with the expansion board.

8.

Install the PCI riser cage (on page

26

).

9.

Install the full-length expansion board retainer (on page

26

).

10.

Install the access panel (on page

24

).

PCI riser board option

CAUTION:

For proper cooling do not operate the server without the access panel, baffles,

expansion slot covers, or blanks installed. If the server supports hot-plug components,

minimize the amount of time the access panel is open.

1.

Power down the server (on page

22

).

2.

Extend the server from the rack (on page

22

).

3.

Remove the access panel (on page

23

).

4.

Remove the full-length expansion board retainer (on page

24

) if any full-length expansion boards are

installed.

5.

Remove the PCI riser cage (on page

25

).

6.

Install the optional riser board.

7.

Install any expansion boards. ("

Expansion board options

" on page

53

)

8.

Install the PCI riser cage (on page

26

).

9.

Install the full-length expansion board retainer (on page

26

) if any full-length expansion boards are

installed.

10.

Install the access panel (on page

24

).

11.

Install the server into the rack.

12.

Power up the server (on page

22

, "

Powering up and configuring the server

" on page

37

).

Advertising