Split port task, Merge sub-ports task, Create single port zone group task – HP 6Gb SAS Switch for HP BladeSystem c-Class User Manual

Page 29: Helpful hints, Available parameters

Advertising
background image

Helpful hints:

•

In dual-domain switch configurations (two switches installed in the same interconnect bay row
of the HP BladeSystem c-Class enclosure), a change to these settings on the active management
switch is automatically propagated to the passive switch.

•

When a P2000 G3 SAS MSA storage enclosure, tape autoloader, or library is included in
the solution with MDS600 or D2600/D2700 storage enclosures:

◦

Multi-initiator mode should be enabled, so that multiple severs can be assigned the zone
group that includes the P2000 G3 SAS MSA or tape device.

◦

Use caution when assigning drive bay zone groups, to prevent them from being assigned
to more than one server.

◦

Consider enabling port-splitting mode, so that multiple tape devices can be connected to
a single switch port.

Split Port task

To divide a switch port into two or four sub-ports, expand the display for the switch in the navigation
tree, select a specific switch port, and then click Split Port.

IMPORTANT:

Port splitting is supported for use with tape devices only.

Available parameters:

Port Splitting
Mode

Controls how many sub-ports will be created from the switch port.

4 sub-ports, 1 phys each—(Default) The sub-ports are labeled A, B, C, and
D.

•

•

2 sub-ports, 2 phys each—The sub-ports are labeled A and B.

Helpful hints

•

Special cables are required when using this feature.

Merge Sub-Ports task

To merge a previously-split switch port from sub-ports back into a single port, expand the display
for the switch in the navigation tree, select a specific switch port, and then click Merge Sub-Ports.
A verification prompt is displayed, requiring confirmation for the action.

Create Single Port Zone Group task

To create a switch-port zone group that includes this one switch port only, expand the display for
the switch in the navigation tree, select a specific switch port, and then click Create Single Port
Zone Group.

Available parameters:

Name

Type a name to assign to the zone group (must be unique, up to 16 characters,
with no spaces).

Split Port task

29