Using flexfabric modules, Figure 42 – HP Insight Management-Software User Manual

Page 71

Advertising
background image

Figure 42 Job details

Replacing the HP 1/10 Gb VC-Enet or the HP 1/10 Gb-Enet modules

To upgrade the HP 1/10 Gb VC-Enet module or the HP 1/10 Gb-Enet module to use the HP VC
Flex-10/10D module see sections

“Replacing VC Ethernet modules with FlexFabric modules in an

existing VCEM managed VC Domain” (page 72)

or

“Replacing VC Ethernet in interconnect bays

three to eight with FlexFabric in an existing VCEM managed VC Domain” (page 72)

.

Using FlexFabric modules

This section describes scenarios to add or replace existing Ethernet and FC modules with FlexFabric
modules.

NOTE:

For general information about replacing VC modules with or without removing the VC

Domain, see

“Replacing VC modules” (page 170)

.

Adding FlexFabric modules to an existing VCEM managed VC Domain

This scenario describes how to add two extra FlexFabric modules in an existing VC Domain with
Ethernet and FC modules. It also describes how to start using FlexFabric functionality in existing
or new server profiles.
1.

Remove the VC Domain from the existing VC Domain Group "A".

2.

Upgrade the VC Domain firmware to the latest version for FlexFabric support.

3.

Add the two FlexFabric modules in both horizontally adjacent bays with appropriate FC SFP+
transceivers.

4.

Create new Ethernet networks and new FC SAN fabrics linked to the new FlexFabric module
uplink ports.

5.

Create a new VC Domain Group using the latest version of VC firmware in VCEM with the
VC Domain HP Virtual Connect FlexFabric 10 Gb/24port module.

6.

Perform the first four steps again for each managed VC Domain that you want to add the HP
Virtual Connect FlexFabric 10 Gb/24port module to and add the VC Domain to the new VC
Domain Group.

Replacing the HP 1/10 Gb VC-Enet or the HP 1/10 Gb-Enet modules

71

Advertising
This manual is related to the following products: