HP XP Racks User Manual

Page 36

Advertising
background image

Table 20 RAID Manager errors related to migration plans (continued)

Required Action

Message

Error Code
(SSB2)

The volume cannot be migrated. Check the
configuration definition file.

If the serial number of the virtual storage machine
is set to the primary and secondary volume, the

20F2

serial number set in the primary volume matches
the serial number set in the secondary volume.
However, the serial numbers of the physical
storage systems and the virtual storage machines
do not match.

The volume cannot be migrated. Check the
configuration definition file.

The pair cannot be operated because the specified
migration source volume is the secondary volume

20F9

of the Business Copy pair whose primary volume
is in the process of the online data migration.

Release the Compatible FlashCopy pair, and then
migrate the volume.

The migration source volume is the source or target
volume of Compatible FlashCopy.

22FA

Release the Compatible FlashCopy pair, and then
migrate the volume.

The migration target volume is the primary or
secondary volume of Compatible FlashCopy.

22FB

Install Auto LUN, and then migrate the volume.

Auto LUN is not installed on the storage system.

2301

Check the configuration information of your
storage system.

The shared memory which is necessary to use Auto
LUN is not installed or the initial setting is not
completed.

2302

The volume cannot be migrated. Check the
configuration definition file.

The LBA size does not match between the
migration target volume and the migration source
volume.

2306

Reduce the number of pairs set in the storage
system, and then migrate the volume.

The maximum number of pairs which can be set
in the storage system is exceeded.

2309

Make the migration target volume off-line from the
host, and then migrate the volume.

The migration target volume is online with the host.

2312

Release the Business Copy pair, and then migrate
the volume.

The migration source volume is set as the leaf
volume of Business Copy

2322

Release the Business Copy pair, and then migrate
the volume.

The migration target volume is set as the secondary
volume of Business Copy.

2328

Release the volume from Auto LUN, and then
migrate the volume.

The migration source volume is already specified
as the target volume of Auto LUN.

232F

The volume cannot be migrated. Check the
configuration definition file.

The number of slots does not match between the
migration target volume and the migration source
volume.

2331

Reduce the number of pair settings of the specified
volume, and then migrate the volume.

You cannot add pair settings any more to the
volume specified as the migration source.

2332

None. The specified volume is not a source
volume.

The volume specified by the migration cancellation
is not a migration source volume

2333

The volume cannot be migrated. Check the
configuration definition file.

The emulation type does not match between the
migration target volume and the migration source
volume.

2336

Release the Business Copy pair, and then migrate
the volume.

The migration source volume is a leaf volume of
Business Copy.

2337

Release the Business Copy pair, and then migrate
the volume.

The migration target volume is a primary volume
of Business Copy.

233B

Release the Business Copy pair, and then migrate
the volume.

The migration target volume is a secondary volume
of Business Copy.

233C

36

Using RAID Manager for Auto LUN

Advertising
This manual is related to the following products: