Auto lun with business copy z or business copy, Auto lun and continuous access journal – HP XP Racks User Manual

Page 15

Advertising
background image

Table 6 Pair status when primary volume of Continuous Access Journal Z delta resync pair is as a
source volume

Status

Pair Name

SUSPEND or DUPLEX

Continuous Access Synchronous Z pair

Any pair status can be acceptable

Continuous Access Journal Z pair

Hold or Hlde

Continuous Access Journal Z pair for delta resync operation

Table 7 Pair status when secondary volume of Continuous Access Journal Z delta resync pair is a
source volume

Status

Pair Name

Any pair status can be acceptable

Continuous Access Synchronous Z pair

SUSPEND

Continuous Access Journal Z pair

Hold or Hlde

Continuous Access Journal Z pair for delta resync operation

Also, the source and target volumes must belong to the same CLPR.

Auto LUN with Business Copy Z or Business Copy

You can use the Business Copy Z pair volumes or the Business Copy Z pair volumes as the Auto
LUN source volume excluding the volumes having some pair statuses or the configurations. For
more information, see

“Supported and prohibited source and target volumes” (page 9)

.

CAUTION:

If you do the Business Copy operation so that the Business Copy pair status becomes COPY
(SP) or PSUS(SP) when Auto LUN and Business Copy share a volume, the Auto LUN process
stops.

If you do the Business Copy Z operation so that the Business Copy Z pair status becomes other
than SP-Pend or V-Split when Auto LUN and Business Copy Z share a volume, the Auto LUN
process stops.

Auto LUN and Continuous Access Journal

You cannot select a volume in COPY or PAIR status as a source volume.

In a 3DC multi-target configuration with Continuous Access Journal and Continuous Access
Synchronous, if you create a Continuous Access Journal pair for a delta resync operation, the
primary volume or the secondary volume of the delta resync pair can be used as a source volume.
To use the primary or secondary volume as a source volume, you must ensure that the status of
each pair in the 3 DC multi-target configuration is as shown in

Table 8 (page 16)

and

Table 9 (page

16)

.