The following information displays for each controller:

•

Model—Displays the type of controller card.

•

Controller Status—Displays the array controller board status. The following values are valid:

OK—The array controller is operating properly.

◦

◦

General Failure—The array controller has failed.

◦

Cable Problem—The array controller has a cable problem. Check all cables to the
controller.

◦

Powered Off—The array controller does not have power. Replace the controller and
restore power to the controller's slot.

◦

Cache Module Missing—The array controller is operating without a cache module which
is an unsupported configuration. Install a cache module to the controller.

◦

Unknown—Indicates that the Storage Agents are unable to determine the status of the
controller. You may need to upgrade the Storage Agents.

•

Current Role—Displays the array controller's current role for duplexed array controllers. The
following values are valid:

◦

Not Duplexed—This array controller is not duplexed.

◦

Active—This duplexed array controller is the active controller.

◦

Backup—This duplexed array controller is the backup controller.

◦

Unknown—Indicates that the Storage Agents are unable to determine the role of the
controller. You may need to upgrade the Storage Agents.

•

Redundancy Mode—Displays the redundancy type for the controller. The following values are
valid:

◦

Not Redundant—This array controller is not in a redundant configuration.

◦

Driver Duplexing—The array controller is using a controller duplexing algorithm
implemented exclusively in the operating system driver.

◦

Firmware Active/Standby—The array controller is using an active/standby algorithm
implemented in the controller firmware and the operating system driver.

◦

Firmware Primary/Secondary—The array controller is using a primary/secondary
algorithm implemented in the controller firmware and the operating system driver.

◦

Firmware Active/Active—The array controller is using an active/active algorithm
implemented in the controller firmware.

◦

Unknown—Indicates that the Storage Agents cannot determine the redundancy type for
the controller. You may need to upgrade the Storage Agents.

•

Redundancy Error—Displays the redundancy error for the controller. The following values are
valid:

◦

No Failure—No failures have been detected.

◦

No Redundant Controller—No redundant controller is installed.

◦

Different Hardware—The other controller indicates a different hardware model.

◦

No Link—A link to the other controller could not be established.

36