Component identification 7

1 - Amber

2 - Green

3 - Green

Interpretation

Off

Off

Off

The cache module is not powered.

Off

Flashing once
every 2 seconds

Flashing once
every 2 seconds

The cache microcontroller is executing from within its
boot loader and receiving new flash code from the host

controller.

Off

Flashing once
per second

Flashing once
per second

The cache module is powering up, and the battery pack
is charging.

Off

Off

Flashing once

per second

The cache module is idle, and the battery pack is

charging.

Off

Off

On

The cache module is idle, and the battery pack is

charged.

Off

On

On

The cache module is idle, the battery pack is charged,

and the cache contains data that has not yet been

written to the drives.

Off

Flashing once
per second

Off

A backup of the DDR content on the cache module is in
progress.

Off

On

Off

The current backup is complete with no errors.

Flashing once
per second

Flashing once

per second

Off

The current backup failed, and data has been lost.

Flashing once
per second

Flashing once
per second

On

A power error occurred during the previous or current
boot. Data may be corrupt.

Flashing once
per second

On

Off

An overtemperature condition exists.

Flashing twice
per second

Flashing twice
per second

Off

The battery pack is not attached.

Flashing twice
per second

Flashing twice

per second

On

The battery has been charging for 10 minutes, but has

not reached sufficient charge to perform a full backup.

On

On

Off

The current backup is complete, but power fluctuations
occurred during the backup.

On

On

On

The cache module microcontroller has failed.