HP XP Racks User Manual

Page 83

Advertising
background image

Where:

*

is the instance number.

HOST

is the host name.

Example:

Error codes appear on the right of the equal symbol (=).

Review RAID Manager error codes in the following topics.

“SSB2 error codes when SSB1 = 2E31/B901/B90A/B90B/B912/D004” (page 83)

“SSB2=B992 error codes when SSB1 = B901 or B90A” (page 91)

SSB2 error codes when SSB1 = 2E31/B901/B90A/B90B/B912/D004

Description

Error code

(SSB2)

The pair cannot be created because the specified P-VOL belongs to a different CLPR than the registered
consistency group CLPR.

4A96

A pair cannot be resynchronized because the specified consistency group does not have the Open/MF
attribute.

4B02

The pair operation was rejected because the necessary shared memory is not mounted in the primary system.

4BE0

The command cannot be executed because the user authentication is not performed.

9100

The pair cannot be created because the system identifier is not correct (left-most number in the 6-digit serial
number).

B920

The consistency group Paircreate or Pairresync was rejected because supported and unsupported microcodes
are used in the DKC.

B923

You cannot run the following operations to a pair in a 2DC configuration:

B927

Swap Suspend

Takeover

The pair cannot be created because the Mirror ID is invalid.

B928

The pair operation was rejected because the online microcode is being replaced.

B929

The pair cannot be created because the specified volume is a command device.

B92A

The pair cannot be created because Cnt Ac-S is not installed.

B934

S-VOL hide mode is not supported.

B935

The required shared memory for operating Continuous Access Synchronous is not installed.

B936

The specified volume is a P-VOL. The pair cannot be released because the P-VOL is specified as an S-VOL.

B93B

The specified volume is an S-VOL. The pair cannot be released because the S-VOL is specified as a P-VOL.

B941

The command was rejected because the volume is unpaired.

B945

The specified LU is not defined. The DKC configuration might have been changed. Restart RAID Manager.

B952

The operation cannot run because pair status is either PSUS (by user) or PSUE (because of failure).

B97B

The command was rejected because the volume is unpaired.

B97C

Troubleshooting using RAID Manager

83