Figure 59 Definition of the protection volumes

Data Protection Facility specifications

Only the permitted volumes can be registered in horcm.conf. When creating the horcm.conf
file, describe volumes only from the view that the host shows. RAID Manager manages mirror
descriptors (Continuous Access Synchronous, Business Copy/MU#0/1/2) as a unit. The Data
Protection Facility has two specifications: one must be a volume that you can see from the host
such as the Inquiry tool, and the other must be a mirror descriptor volume that was registered in
horcm.conf

. The following table shows the registration for the mirror descriptor.

Table 40 Registration for the mirror descriptor

Mirror Descriptor in horcm.conf

Volumes in
horcm.conf

Business Copy

Continuous Access
Synchronous

MU#2

MU#1

MU#0

none

E

none

E

none

E

none

E

-

-

-

-

-

-

-

-

Unknown

-

permitted
volumes

-

permitted
volumes

-

permitted
volumes

-

permitted
volumes

/dev/rdsk/c0t0d0

-

-

-

-

-

-

-

-

Unknown

Legend:

E: Mirror descriptor volume to be registered in horcm.conf.

Unknown: Volumes that own host cannot recognize, even though volumes were registered in horcm.conf.

RAID Manager permits operation after the permission command at startup of HORCM.
The target is volume that was registered in the horcm.conf file.

The permission command is necessary to permit the protected volume at first. The
permission

command compares an identification for volumes of horcm.conf to all of own

host volumes, and the result is registered within HORCM. And HORCM makes tables for
protected volume and permitted volumes from horcm.conf and Inquiry result. Inquiry result
is based on configuration of Data Retention. When controlling pair volumes, requests to
protected volumes are rejected with error code EX_ENPERM.

The Data Protection Facility is based on the host side view at the result of Data Retention. You
need to configure Data Retention before RAID Manager operation. RAID Manager checks
Data Retention by Inquiry within RAID Manager.

The Data Protection Facility can be enabled separately for each command device. If you want
to use protection and non-protection modes in the same storage system at the same time, you
can define two (or more) command devices: one with protection ON, one with protection
OFF. Protection mode is enabled for the host that has Data Retention and ON command
device.