Table 6 Mirror descriptors and group assignments

Cnt Ac-J only

BC (Snapshot)
only

MU#0

HORCM_DEV parameter in configuration file

MU#1-#3

MU#1-#2
(MU#3-#63)

BC

Cnt Ac-S/
Cnt Ac-J

-

-

oradev1

oradev1

HORCM_DEV

#dev_group dev_name port# TargetID LU# MU#

Oradb oradev1 CL1-D 2 1

-

oradev11

oradev1

oradev1

HORCM_DEV

oradev21

#dev_group dev_name port# TargetID LU# MU#

Oradb oradev1 CL1-D 2 1

Oradb1 oradev11 CL1-D 2 1 1

Oradb2 oradev21 CL1-D 2 1 2

-

oradev21

oradev11

oradev1

HORCM_DEV

oradev31

#dev_group dev_name port# TargetID LU# MU#

Oradb oradev1 CL1-D 2 1

Oradb1 oradev11 CL1-D 2 1 0

Oradb2 oradev21 CL1-D 2 1 1

Oradb3 oradev31 CL1-D 2 1 2

-

-

oradev1

-

HORCM_DEV

#dev_group dev_name port# TargetID LU# MU#

Oradb oradev1 CL1-D 2 1 0

-

oradev11

oradev1

-

HORCM_DEV

oradev21

#dev_group dev_name port# TargetID LU# MU#

Oradb oradev1 CL1-D 2 1 0

Oradb1 oradev11 CL1-D 2 1 1

Oradb2 oradev21 CL1-D 2 1 2

oradev21

-

oradev11

oradev1

HORCM_DEV

oradev31

#dev_group dev_name port# TargetID LU# MU#

Oradb oradev1 CL1-D 2 1

oradev41

Oradb1 oradev11 CL1-D 2 1 0

Oradb2 oradev21 CL1-D 2 1 h1

Oradb3 oradev31 CL1-D 2 1 h2

Oradb4 oradev41 CL1-D 2 1 h3

Cascading connection and configuration files

A volume of the cascading connection describes entity in a configuration definition file on the same
instance, and classifies connection of volume through the mirror descriptor. In case of Continuous
Access Synchronous/Business Copy cascading connection, too, the volume entity describes to a
configuration definition file on the same instance. The following figure shows an example of this.

RAID Manager instance components on the host server

35