User authentication – HP XP P9500 Storage User Manual

Page 54

Advertising
background image

Specify the number (from 0 to 7) to <value> depending on the contents of the security which you
want, in reference with the following table.

Table 13 Security setting for virtual command device

Security to be set

Command device setting

Value specifying
to <value>

Group information
acquisition

User authentication

Security

No security

0

0

0

0

Only HORCM_DEV
allowed

1

0

0

1

User authentication
required

0

1

0

2

User authentication
required

1

1

0

3

Only HORCM_DEV
allowed

CMD security

0

0

1

4

CMD security

1

0

1

5

Only HORCM_DEV
allowed

CMD security

0

1

1

6

User authentication
required

CMD security

1

1

1

7

User authentication
required

Only HORCM_DEV
allowed

Notes:

Only HORCM_DEV allowed: means to be able to perform the operation for only paired logical volumes described
at HORCM_DEV.

User authentication required: means that only the commands issued by the authorized users can be executed.

CMD security: means that only the devices recognizable from the host can be operated. For details about CMD
security, please refer to "

(page 175)

".

User authentication

RAID Manager allows user authentication by using the user information managed by Remote Web
Console and the SVP.

User authentication is arbitrary in the Replication operation in the in-band method while the operation
by user authentication is mandatory in the configuration information operation and in the out-of-band
method.

To enable the user authentication function, the user authentication mode of the command device
accessed by RAID Manager must be enabled.

The user authentication function inputs a login command from the client (server) and, to authenticate
the user ID and password sent from RAID Manager and the same types of information maintained
by the storage system, issues an authentication request to the authentication module (SVP).

If the user ID and password sent from RAID Manager are authenticated, RAID Manager, for the
once authenticated user (the user on the client starting up RAID Manager), stores the user ID and

54

RAID Manager functions on the P9500

Advertising