Replacing the controller cache battery pack – HP StorageWorks 1000 Modular Smart Array User Manual

Page 18

Advertising
background image

MSA1000 Controller

18

MSA1000 Controller User Guide

Replacing the Controller Cache Battery Pack

WARNING:

There is a risk of explosion, fire, or personal injury if the battery

pack is replaced incorrectly or mistreated. To reduce the risk:

■

Do not attempt to recharge the battery outside of the controller.

■

Do not expose to water, or to temperatures higher than 60°C.

■

Do not abuse, disassemble, crush, puncture, short external contacts, or

dispose of in fire or water.

■

Replace only with the spare designated for this product.

■

Array Accelerator battery disposal should comply with local regulations.

Alternatively, return them by established parts return methods to

Hewlett- Packard Corporation for disposal.

Caution:

It is important to follow these instructions when replacing

components in the MSA1000. If the procedure is done improperly, it is

possible to lose data or damage equipment. Refer to the “

Electrostatic

Discharge

” appendix for important information on using the proper

procedures.

To remove the old NiMH battery pack:

1. Remove the MSA1000 Controller Cache, as instructed in the previous

section, “

Replacing the MSA1000 Controller Cache

.”

2. Push down on the bottom clip of the battery pack, attached near the lower

corner of the Array Accelerator.

See

Figure 6

for an illustration.

Advertising