HP StorageWorks 1000 Modular Smart Array User Manual
Page 53

Controller Display Messages
53
300 RECOVERY ROM
AUTOFLASH
STARTED
Informational
Indicates that the array
controller has detected that
the firmware’s backup
recovery ROM image is
invalid and is copying the
current active firmware
image into the backup
recovery ROM.
301 RECOVERY ROM
AUTOFLASH DONE
Informational
Indicates that the array
controller has successfully
completed the process of
copying the current active
firmware image into the
backup recovery ROM.
302 RECOVERY ROM
AUTOFLASH FAILED
Error
Indicates that the array
controller failed to copy the
current active firmware
image into the backup
recovery ROM. Recovery
ROM support is disabled.
Remove the failing
array
controller, wait 10 seconds,
and then reinsert the array
controller insuring that it is
fully seated in the chassis.
The ROM autoflash process
will be attempted again.
Should the issue persist
please contact HP support.
Table 3: LCD Message Descriptions
Message
Type
Description
Action