Diagnosing array problems 27

Diagnosing array problems

In this section

Controller board runtime LEDs.................................................................................................................. 27

Cache module LEDs................................................................................................................................ 28
Diagnostic tools ..................................................................................................................................... 29

Controller board runtime LEDs

NOTE:

During server power-up, each runtime LED illuminates randomly until POST has

finished.

LED ID

Color

LED name and interpretation

0

Amber

CR510: Controller Failure LED. The controller firmware has detected an error.

1

Amber

CR511: Drive Failure LED. A physical drive connected to the controller has failed.
Check the Fault LED on each drive to determine which drive has failed.

2

Blue

CR512: Activity LED for SAS port 2I.

3

Blue

CR513: Activity LED for SAS port 1E and 1I.

4

Green

CR514: Command Outstanding LED. The controller is working on a command
from the host driver.

5

Blue

CR515: Heartbeat LED. This LED blinks every 2 seconds to indicate the controller

health.

6

Green

CR516: Gas Pedal LED. This LED, together with item 7, indicates the amount of

controller CPU activity. For details, refer to the following table.

7

Green

CR517: Idle Task LED. This LED, together with item 6, indicates the amount of
controller CPU activity. For details, refer to the following table.

8

Amber

CR507: Battery Status LED. For interpretation, refer to "Cache module LEDs (on
page

28

)."

9

Green

CR508: Battery Charging LED. For interpretation, refer to "Cache module LEDs
(on page

28

)."

Advertising