If more than one option is being installed, read the installation instructions for all the hardware options

and identify similar steps to streamline the installation process.

WARNING:

To reduce the risk of personal injury from hot surfaces, allow the drives and the

internal system components to cool before touching them.

CAUTION:

To prevent damage to electrical components, properly ground the server before

beginning any installation procedure. Improper grounding can cause electrostatic discharge.

Memory options

For server-specific memory installation guidelines, refer to the installation sheet that ships with the server.

Interleaving and non-interleaving memory configuration

This server supports both interleaving and non-interleaving memory configurations. Interleaving memory
increases bandwidth by allowing simultaneous access to more than one block of data (for example,

overlapping Read-Writes). This is accomplished by dividing the system memory between pairs of DIMMs
and Writing-Reading blocks of data to/from both simultaneously. In order to take advantage of memory
interleaving, identical DIMMs must be installed in pairs. DIMMs can also be installed singularly in slot 1

only if memory interleaving is not desired.

Installing DIMMs

1.

Power down the server (on page

6

).

2.

Remove the server from the rack (on page

6

).

3.

Remove the primary access panel (on page

7

).

4.

Open the DIMM slot latches.