HP XP Continuous Access Software User Manual
Page 194
Advertising

194
HP StorageWorks Disk Array XP RAID Manager: User’s Guide
Other than 0 to 127 (For the error cause and details, see the execution logs):
236:EX_ENQVOL
237:EX_CMDIOE
235:EX_EVOLCE . . . When the –c argument is specified
242:EX_ENORMT. . . When the –c argument is specified
16:EX_EXTCTG
214:EX_ENQCTG
When a volume group contains volumes in different states, one state will
take precedence and will be reported for the group as shown in the
following table.
Option
COPY
PSUE
PDUB
PFUS
PSUS
PFUL
PAIR
Group
Status
–s
1
x
x
x
x
x
x
COPY*
0
1
x
x
x
x
x
PSUE
0
0
1
x
x
x
x
PDUB
0
0
0
1
x
x
x
PFUS
0
0
0
0
1
x
x
PSUS
0
0
0
0
0
1
x
PFUL
0
0
0
0
0
0
1
PAIR
–ss
1
x
x
x
x
x
x
COPY*
0
1
x
x
x
x
x
PSUE
0
0
1
x
x
x
x
PDUB
0
0
0
x
x
1
x
PFUL
0
0
0
x
x
0
1
PAIR
0
0
0
1
0
0
0
PFUS
0
0
0
0
1
0
0
PSUS
Advertising
This manual is related to the following products: