Command errors, Command errors 273 – HP XP Continuous Access Software User Manual

Page 273

Advertising
background image

Troubleshooting RAID Manager

273

Command errors

Command Error Problem

Action

EX_ATTDBG

This command failed to communicate
with RM, or a log directory file could
not be created.

Verify that RM is functioning properly.

EX_ATTHOR

Connection could not be made with
RM.

Verify that RM has started and that the
correct HORCMINST value has been
defined.

EX_CMDIOE

The request to the command device
either failed or was rejected.

Check to see whether the syslog file of
the host reports an Illegal Request (0x05)
Sense Key, if so, then verify:

• The BC/CA functions are installed on

the disk array;

• The ESCON RCP and LCP ports are

set properly;

• The CU paths have been established;

• The target volume is available.

EX_CMDRJE

The request to the command device
either failed or was rejected.

Verify the following:

• The BC/CA functions are installed on

the disk array.

• The ESCON RCP and LCP ports are

set properly.

• The CU paths have been established.

• The target volume is available.

EX_COMERR

This command failed to communicate
with RM.

Verify that RM is running.

EX_ENAMLG

Undefined error.

Call the HP support center.

(continued)

Advertising