Manual path switching, Manual path switching -21 – HP XP P9500 Storage User Manual

Page 43

Advertising
background image

When intermittent errors

#

occur on paths and you are using the automatic

failback function, the path status might frequently alternate between the

online and offline statuses. In such a case, because the performance of I/Os

will most likely decrease, if there are particular paths in which intermittent

errors might be occurring, we recommend that you set up intermittent error

monitoring so you can detect these paths, and then remove them from those

subject to automatic failbacks.

You can specify the automatic failback function or intermittent error by the
dlnkmgr command's set operation. For details on the set operation, see

set

(Sets Up the Operating Environment) on page 6-14

.

#

An intermittent error means an error that occurs irregularly because of

some reason such as a loose cable connection.

Manual Path Switching

You can switch the status of a path by manually placing the path online or

offline. Manually switching a path is useful, for example, when system

maintenance needs to be done.

You can manually place a path online or offline by doing the following:

Execute the dlnkmgr command's online or offline operation.
For details on the online operation, see

online (Places Paths Online) on

page 6-10

. For details on the offline operation, see

offline (Places

Paths Offline) on page 6-5

.

However, if there is only one online path for a particular LU, that path cannot

be manually switched offline. Also, a path with an error that has not been

recovered from yet cannot be switched online.

HDLM uses the same algorithms to select the path that will be used next,

regardless of whether automatic or manual path switching is used.

When using the Thunder 9500V series, or Hitachi AMS/WMS series, HDLM will

select the next path to be used first from among the online owner paths, and

then from the online non-owner paths. When the Lightning 9900 series,

Lightning 9900V series, Hitachi USP, Universal Storage Platform V/VM, Virtual

Storage Platform, Hitachi AMS2000 series, or Hitachi SMS is being used, all

the paths that access the same LU as the path that is currently being used

are candidates for the switching destination path.

Executing the online operation places the offline path online. For details on

the online operation, see

online (Places Paths Online) on page 6-10

. After a

path status is changed to online, the path can be selected as a useable path

by HDLM in the same manner as automatic path switching. When using the

Thunder 9500V series, or Hitachi AMS/WMS series, HDLM selects the path to

use from online owner paths, and then from online non-owner paths. When

the Lightning 9900 series, Lightning 9900V series, Hitachi USP, Universal

Storage Platform V/VM, Virtual Storage Platform, Hitachi AMS2000 series, or

Hitachi SMS is being used, since all the paths are owner paths, the path to

HDLM Functions

2-21

Hitachi Dynamic Link Manager User Guide (for Linux(R))