If an error occurs in the only available online path for an LU, the status of the

path will change to Online(E).

If you are using the automatic failback function, after the path has recovered

from the error, HDLM will automatically place the path online.

When you are using intermittent error monitoring, the path in which the

intermittent error occurred is not automatically placed online when the path

recovers from the error. In such a case, place the path online manually.

Note:

If there is a path failure immediately after a path is taken offline by using

either the an HDLM command, the status might change from Offline(C)

to Offline(E). If an offline operation was just performed, wait about 1

minutes, check the path status by using an HDLM command, and then

make sure that the status has changed to Offline(C). If it is still
Offline(E), retry the offline operation.

Monitoring Intermittent Errors (Functionality When

Automatic Failback Is Used)

An intermittent error refers to an error that occurs irregularly because of

something like a loose cable. In such a case, I/O performance might decrease

while an automatic failback is being performed to repair an intermittent error.

This is because the automatic failback operation is being performed

repeatedly (because the intermittent error keeps occurring). To prevent this

from happening, HDLM can automatically remove the path where an

intermittent error is occurring from the paths that are subject to automatic

failbacks. This process is called intermittent error monitoring.

We recommend that you use intermittent error monitoring along with the

automatic failback function.

A path in which an error occurs a specified number of times within a specified

interval is determined to have an intermittent error. The path where an

intermittent error occurs has an error status until the user chooses to place

the path back online. Failbacks are not performed for such paths. This status

is referred to as the not subject to auto failback status.

Checking Intermittent Errors

You can check the paths in which intermittent errors have occurred by

viewing the execution results of the HDLM command's view operation.

For details on the view operation, see

view (Displays Information) on page

6-28

.

Setting Up Intermittent Error Monitoring

When you enable the intermittent error monitoring function, specify the

following monitoring conditions: the error monitoring interval, and the

2-24

HDLM Functions

Hitachi Dynamic Link Manager User Guide (for Linux(R))