Error management, Error management -30 – HP XP P9500 Storage User Manual

Page 52

Advertising
background image

For example, in a normal state, I/O operations are not performed on the

paths coming from the standby host in the cluster configuration or on non-

owner paths (that is, some of the paths that access a Thunder 9500V series

and Hitachi AMS/WMS series storage system). Because of this, for the

standby host or for a host connected to non-owner paths, we recommend

that you use path health checking to detect errors. This enables the system

to use the most up-to-date path-status information when selecting the next

path to use.

You can configure path health checking by executing the dlnkmgr command's
set operation. For details on the set operation, see

set (Sets Up the

Operating Environment) on page 6-14

.

Error Management

HDLM collects information for troubleshooting into log files. HDLM can also

filter error information according to the error level when collecting the

information.

Figure 2-15 Flow of Data When Collecting Error Information on page 2-31

shows the flow of data when collecting error information.

2-30

HDLM Functions

Hitachi Dynamic Link Manager User Guide (for Linux(R))

Advertising
This manual is related to the following products: