HP Surestore 2.15 Tape Library User Manual

Page 86

Advertising
background image

4-36

Library Operation

Using Online Repair

6. Press

NEXT

until

DRV # OFF FAILED

displays then press

ENTER

.

7.

CHANGE CONFIRMED

displays briefly, then

ONLINE REPAIR*

displays. Press

ENTER

.

8.

DRIVE POWER*

displays.

9. Press

NEXT

or

PREV

until

DRIVE STATUS

displays, then press

ENTER

.

10. Press

NEXT

or

PREV

until

DRV # OFF FAILED

displays (where “#” is the

number of the drive that was just taken offline) then press

ENTER

.

11.

DRV # OFF FAILED

displays, where “#” is the drive number and “OFF

FAILED” is flashing.

12. Press

NEXT

until

DRV # ON GOOD

displays, then press

ENTER

.

13.

SETTING UP DRIVE

displays briefly while the drive communication

tests run, then

CHANGE CONFIRMED

displays briefly, then

ONLINE

REPAIR*

displays.

14. Press

CANCEL

twice to return to the drive numbers and status indicators

(“ready” state).

15. Try reading the damaged tape again.

•

If the tape can be read, back up data from the damaged cartridge to
another tape cartridge and discard the damaged one.

•

If the tape cannot be read, call a service representative.