Library Operation

Troubleshooting

Table 4-11

Troubleshooting

Problem

Solution

Library will not power on.

•

Make sure the power cord connections are tight.

•

Make sure the power switch is switched on. (The power
switch is located on the library control panel, see Figure 4-1
on page 4-3.)

•

Make sure the power outlet is operating.

•

Replace the power cord with a known good one.

•

If the library still won’t power on, call a service
representative.

Power on self test failed.

DEVICE FAILED

displays.

•

Verify that all tapes in the bulk load magazines are fully
inserted in the magazines, and that the magazines are
securely locked into position inside the tape library.

•

Press the power switch off and then on again. (See the
caution note at the end of this table.)

•

If the power on test continues to fail, press

ENTER

, write

down the displayed error code, and call a service
representative for assistance.

DEVICE FAILED

displays.

Hardware Error #61
(External SCSI cables) is
reported.

•

Make sure that only differential SCSI device type is used on
the SCSI bus.

•

Verify that the library SCSI selector switch is set correctly
(differential).

•

Verify that the bus is properly terminated.

The library’s power failed
while a cartridge was in the
drive and did not return to
the drive status indicators
("ready" state) after the
power came back on.

•

Press the power switch off and then on again. (See the
caution note at the end of this table.)

•

If the power on test is unsuccessful, switch off the power.
Call a service representative for assistance.