Connecting external storage, Sas cable part numbers – HP Smart Array P600-Controller User Manual

Page 11

Advertising
background image

Installing the controller hardware

11

CAUTION: Do not operate the server for long periods with the

access panel open or removed. Operating the server in this manner
results in improper airflow and improper cooling that can lead to thermal
damage.

9.

If the controller was hot-plugged, power up the slot.

Connecting external storage

1.

Power down the server.

2.

Connect an external SAS cable to the external port of the controller.

NOTE: You do not have to disconnect any internal drives on

shared internal port 1I because the controller preferentially discovers
devices attached to port 1E. However, drives on the shared internal port
are unavailable until you disconnect the external storage device.

3.

Tighten the lock screws on the cable connector.

4.

Attach the other end of the cable to the SAS input connector of the external

storage enclosure.

IMPORTANT: Drives that are to be used in the same array must

be of the same type, either all SAS or all SATA. (Parallel SCSI drives
cannot be used with this controller.)

5.

Tighten the lock screws on the cable connector.

6.

Power up the enclosure.

7.

Power up the server.

SAS cable part numbers

NOTE: If you require additional cables, order them by the option kit

number.

Cable length

Option kit number

Cable assembly number

1.0 m (3.3 ft)

389665-B21

361317-001

2.0 m (6.6 ft)

389668-B21

361317-002

4.0 m (13 ft)

389671-B21

361317-004

Advertising