HP Smart Array P600 Controller for Integrity Servers User Guide

Online/Activity
LED (green)

Fault/UID LED
(amber/blue)

Interpretation

On, off, or flashing Steadily blue

The drive is operating normally, and it has been selected by a
management application.

On Amber,

flashing

regularly (1 Hz)

A predictive failure alert has been received for this drive.

Replace the drive as soon as possible.

On

Off

The drive is online, but it is not active currently.

Flashing regularly
(1 Hz)

Amber, flashing
regularly (1 Hz)

Do not remove the drive. Removing a drive may terminate
the current operation and cause data loss.

The drive is part of an array that is undergoing capacity
expansion or stripe migration, but a predictive failure alert has
been received for this drive. To minimize the risk of data loss,
do not replace the drive until the expansion or migration is
complete.

Flashing regularly
(1 Hz)

Off

Do not remove the drive. Removing a drive may terminate
the current operation and cause data loss.

The drive is rebuilding, or it is part of an array that is undergoing
capacity expansion or stripe migration.

Flashing
irregularly

Amber, flashing
regularly (1 Hz)

The drive is active, but a predictive failure alert has been
received for this drive. Replace the drive as soon as possible.

Flashing
irregularly

Off

The drive is active, and it is operating normally.

Off

Steadily amber

A critical fault condition has been identified for this drive, and
the controller has placed it offline. Replace the drive as soon as
possible.

Off Amber,

flashing

regularly (1 Hz)

A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.

Off

Off

The drive is offline, a spare, or not configured as part of an
array.