Problems running the setup utility – HP Netserver L Server series User Manual

Page 112

Advertising
background image

Chapter 12

Troubleshooting

106

Figure 12-3. Battery on System Board

7. Insert the new battery with the positive sign (+) facing up. Push the battery

down into the socket.

The battery should snap into place. Ensure the spring latch holds the
battery firmly.

8. Replace the PCI card cage, processor cooling fan, and cover.

9. Power on the Netserver.

10. Press <F2> to run the Setup Utility and reset the CMOS settings. Refer to

“Setup (BIOS) Utility” in Chapter 10, "Configuring the HP Netserver."

Problems Running the Setup Utility

If you cannot run the Setup Utility, the HP Netserver's configuration in CMOS
memory may have become corrupt. The only way to recover from a corrupted
configuration is to clear it. Refer to "Clearing the CMOS Configuration," earlier in
this chapter.