Installing a power supply module – HP Netserver L Server series User Manual

Page 84

Advertising
background image

Chapter 9

Connecting the Monitor, Keyboard, Mouse, and UPS

78

Installing a Power Supply Module

The HP Netserver LP 2000r comes with one power supply module. A second
power supply module for redundancy is optional. If only one power supply
module is used, it must be installed in power supply bay 2, and a power supply
filler panel must be installed in the empty bay 1. Each power supply has its own
power cord (see Figure 9-2).

CAUTION

Operating the HP Netserver without a power supply filler
panel in an empty power supply bay could cause excessive
EMI or thermal damage to the Netserver.

Power Supply Bay #1

Power Supply Bay #2

AC for Power Supply Bay #1

AC for Power Supply Bay #2

Figure 9-2. Power Supply Connectors

1. Remove the power supply filler panel from the empty power supply bay:

a. Pinch the release lever on the filler panel and pull the lever down.

b. Slide the filler panel out of the power bay. See Figure 9-3.

Save the power supply filler panel for future use. The filler panel must
be used in the empty power supply bay whenever you operate the HP
Netserver with a single power supply module.

Advertising