Connecting hosts

Host ports and replication

MSA 2040 SAN controller modules can use qualified SFP options of the same type, or they can use a

combination of qualified SFP options supporting different interface protocols. If you use a combination of

different protocols, then host ports 1 and 2 are set to FC (either both16 Gbit/s or both 8 Gbit/s), and host

ports 3 and 4 must be set to iSCSI (either both 10GbE or both 1 Gb). Each host port can perform I/O or

replication. In combination environments one interface—for example FC—might be used for I/O, and the

other interface type—10GbE or 1 Gb iSCSI—might be used for replication.

Single-controller configuration

One server/single network/two switches

The diagram below shows the rear panel of two MSA 2040 SAN controller enclosures with both I/O and

replication occurring on the same network. Each enclosure is equipped with a single controller module.

The controller modules can use qualified SFP options of the same type, or they can use a combination of

qualified SFP options supporting different interface protocols.

Figure 25 Connecting two storage systems for Remote Snap: one server/two switches/one location

Host ports used for replication must be connected to at least one switch. For optimal protection, use two

switches, with one replication port from each controller connected to the first switch, and the other

replication port from each controller connected to the second switch. Using two switches in tandem avoids

the potential single point of failure inherent to using a single switch.

Dual-controller configuration

Each of the following diagrams show the rear panel of two MSA 2040 SAN controller enclosures

equipped with dual-controller modules. The controller modules can use qualified SFP options of the same

type, or they can use a combination of qualified SFP options supporting different interface protocols.

Multiple servers/single network

The diagram below shows the rear panel of two MSA 2040 SAN controller enclosures with both I/O and

replication occurring on the same physical network.

Figure 26 Connecting two storage systems for Remote Snap: multiple servers/one switch/one location

6Gb/s

S

S

A

6Gb/s

S

S

A

MSA 2040 SAN Storage system

I/O switch

(replication)

Switch

To host server

MSA 2040 SAN Storage system

IOM blank

IOM blank

6Gb/s

S

S

A

6Gb/s

S

S

A

6Gb/s

S

S

A

6Gb/s

S

S

A

MSA 2040 SAN Storage system

Switch

To host server(s)

MSA 2040 SAN Storage system

Advertising