Backplane information, Asset information, Power supply information – HP Insight Management Agents User Manual

Page 63

Advertising
background image

Backplane Information

This information is not available for all types of storage systems.

•

Firmware Revision displays the revision level of storage system backplane.

•

Drive Bays displays the number of drive bays on this storage system backplane.

•

Duplex displays the storage system backplane duplex option. The following values are
possible:
— Not Duplexed - This storage system is not duplexed.
— Duplex Top - This is the top portion of a duplexed storage system.
— Duplex Bottom - This is the bottom portion of a duplexed storage system.
— Unknown - The Storage Agents are unable to determine if this storage system is

duplexed.

Asset Information

This information is not available for all types of storage systems.

•

Board displays the type of board (system, power, or SCSI).

•

Serial Number displays the serial number of the board.

•

Board Revision displays the revision number of the board.

Power Supply Information

This information is not available for all types of storage systems.

•

Description displays the description of the power supply. The following values are possible:
— Power Bay 1 - The power supply is installed in the first power supply bay.
— Power Bay 2 - The power supply is installed in the second power supply bay.
— Power Supplies - This is a composite of all the installed power supplies.
— Unknown - The Storage Agents do not recognize the bay. You may need to upgrade

your software.

•

Status displays the status of the power supply. The following values are possible:
— OK - A power supply is installed and operating normally.
— Degraded - At least one of multiple power supplies has failed or lost power.
— Failed - A power supply is installed and is no longer operating. Replace the power

supply.

— Not Installed - Nothing is installed in this power supply bay.
— Unknown - The Storage Agents are unable to determine if this storage system power

supply bay is occupied.

•

Serial Number displays the serial number of the power supply. Use this information for
identification purposes.

•

Board Revision displays the board revision of the power supply.

•

Firmware Revision displays the firmware revision of the power supply.

Storage Agent

63

Advertising