Sub-system classification, Power subsystem – HP Insight Management Agents User Manual

Page 106

Advertising
background image

◦

noDigest

◦

crc32c

•

Data Integrity displays the iSCSI data digest scheme in use within this connection. The following
values are valid:

◦

none

◦

other

◦

noDigest

◦

crc32c

Sub-system Classification

Power Subsystem

This section displays information about the redundant power supplies. The following entries may
be displayed:

•

Location—Displays the bay where the power supply is located.

•

Condition—Displays the status of the power supply. The following values are possible:

OK—A power supply is installed and operating normally.

◦

◦

Failed—A power supply is installed and is no longer operating. Replace the power supply.

◦

Not Installed—Nothing is installed in this power supply bay.

◦

Unknown—The Server Agent is unable to determine if this storage system power supply
bay is occupied.

•

Serial Number—Displays the serial number of the power supply. This information can be used
for identification purposes.

•

Firmware Revision—Displays the firmware revision of the power supply.

•

Present—Represents whether the power supply is present in the chassis.

•

Status—Represents the status of the power supply in the chassis. The following values are
possible:

◦

No Error

◦

General Failure

◦

Bist Failure

◦

Fan Failure

◦

Temperature Failure

◦

Interlock Open

◦

EPROM Failed

◦

VREF Failed

◦

DAC Failed

◦

RAM Test Failed

◦

Voltage Channel Failed

◦

Orring Diode Failed

◦

Brownout

◦

Give Up On Startup

106 Agent information

Advertising